Light Path Diagnostics - IBM 8832L1X Maintenance And Troubleshooting Manual

Server compute blade
Table of Contents

Advertisement

NOTE
See "System" on page 130 to determine which components should be replaced by a field
service technician.
Error code/symptom
01298101
(System BIOS installed on this server
does not support level of processor)
01298102
(System BIOS installed on this server
does not support level of processor)
I9990300
(Boot Sequence could not be retrieved
from BMC using default boot
sequence)
I9990301
(Hard disk sector error)
I9990305
(Hard disk sector error, no operating
system installed)
I9990306
(Timed out waiting on Boot Permission
from Management Module)
I9990650
(AC power has been restored)

Light Path Diagnostics

Lit blade-error
LED
None
An error has occurred and cannot be
isolated, or the service processor has failed.
108
1. Ensure that microprocessor 1 is supported.
2.
Microprocessor 1.
1. Ensure that microprocessor 2 is supported.
2.
Microprocessor 2.
1. Reseat microprocessor.
2.
Reseat management module.
1. Hard disk drive
2.
SCSI backplane
3.
Cable
4.
System board assembly
Install operating system to hard disk.
1. Reseat microprocessor.
2.
Reseat management module.
1. Check cable.
2.
Check for interruption of power.
3.
Power cable.
Cause
Intel® Server Compute Blade SBX82: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action
Action
An error has occurred that is not
represented by a Light Path
Diagnostics LED. Check the system
error log for more information about the
error.