Using switch block 2 (SW2)

You must remove the blade server from the SBCE unit, open the cover, and press the Light Path
Diagnostics button to light any error LEDs that were turned on during processing. The following
illustration and Table 1 on page 14 show the location and the settings for SW2.
Figure 4. System board switch block (SW2) location
Table 1. Switch block 2 (SW2) and settings
Switch number
SW2
14
Switch block (SW2)
Switch block: Eight switches
1 - BIOS backup page jumper.
- Open: the BIOS boots from the Primary BIOS page.
- Closed: the BIOS boots from the backup BIOS page.
2 - Wake on LAN Bypass
- Open: Enabled
- Closed: Disabled (default)
3 - Reserved
4 - Reserved
5 - Reserved
6 - Clear CMOS
- Open: Disabled
- Closed: Enabled
7 - Reserved
8 - Bypass power-on password
- Open: Disabled (default)
- Closed: Enabled