Error code/symptom
2462
(Video memory configuration error)
5962
(IDE CD-ROM drive configuration
error)
8603
(Pointing-device error)
0001200
(Machine check architecture error)
00012000
(Microprocessor machine check)
00019501
(Microprocessor 1 is not functioning -
check VRM and microprocessor LEDs)
00019502
(Microprocessor 2 is not functioning –
check VRM and microprocessor LEDs)
00019701
(Microprocessor 1 failed)
00019702
(Microprocessor 2 failed)
00151200
(microprocessor machine check)
00180200
(No more I/O space available for
adapter)
01295085
(ECC checking hardware test error)
1. Verify that the keyboard/mouse/video select button LED
on the front of the blade server is on, indicating that the
blade server is connected to the shared monitor.
2.
Verify that the monitor is connected correctly to the SBCE unit.
3.
Video adapter (if installed).
4.
System board assembly.
1. Run the Configuration/Setup Utility program.
2.
CD-ROM drive.
3.
CD-ROM power cable.
4.
IDE cable.
5.
System board assembly.
6.
Battery.
1. Pointing device
2.
System board assembly
1. Microprocessor 1
2.
Optional microprocessor 2
3.
System board assembly
1. Microprocessor
2.
System board assembly
1. Microprocessor 1
2.
System board assembly
1. Microprocessor 2
2.
System board assembly
1. Microprocessor 1
2.
System board assembly
1. Microprocessor 2
2.
System board assembly
1. Run the Configuration/Setup Utility program.
2.
Microprocessor (check error LED for failing microprocessor).
3.
System board assembly.
1. Run the Configuration/Setup Utility program.
2.
Failing adapter.
3.
System board assembly.
1. System board assembly
2.
Microprocessor
FRU/action