NOTE
See "System" on page 130 to determine which components should be replaced by a field
service technician.
Symptom
The SCSI storage expansion
unit used to work but does
not work now.
NOTE
See "System" on page 130 to determine which components should be replaced by a field
service technician.
Symptom
Not all drives are recognized
by the hard disk drive
diagnostic test (Fixed Disk
test).
System stops responding
during hard disk drive
diagnostic test.
NOTE
See "System" on page 130 to determine which components should be replaced by a field
service technician.
Symptom
Problems such as broken
cover locks or indicator LEDs
not working
112
Expansion enclosure problems
FRU/action
1. Verify that the enclosure is installed correctly.
2.
For more information, see the SCSI storage expansion unit
documentation.
Hard disk drive problems
FRU/action
1. Remove the first drive not recognized and try the hard disk drive
diagnostic test again.
2.
If the remaining drives are recognized, replace the drive you removed
with a new one.
1. Remove the hard disk drive being tested when the computer
stopped responding and try the diagnostic test again.
2.
If the hard disk drive diagnostic test runs successfully, replace the drive
you removed with a new one.
General problems
FRU/action
Broken CRU/FRU
Intel® Server Compute Blade SBX82: Hardware Maintenance Manual and Troubleshooting Guide