NOTE
See "System" on page 130 to determine which components should be replaced by a field
service technician.
Beep/symptom
1-1-2
(Microprocessor register test
failed)
1-1-3
(CMOS write/read test failed)
1-1-4
(BIOS ROM checksum failed)
1-2-1
(Programmable Interval Timer
failed)
1-2-2
(DMA initialization failed)
1-2-3
(DMA page register write/read
failed)
1-2-4
(RAM refresh verification failed)
1-3-1
(first 64K RAM test failed)
1-3-2
(first 64K RAM parity test failed)
2-1-1
(Secondary DMA register failed)
2-1-2
(Primary DMA register failed)
2-1-3
(Primary interrupt mask register
failed)
2-1-4
(Secondary interrupt mask
register failed)
2-2-1
(Interrupt vector loading failed)
2-2-2
(Keyboard controller failed)
96
1. Optional microprocessor (if installed)
2.
Microprocessor
3.
System board assembly
1. Battery
2.
System board assembly
1. Flash BIOS.
2.
DIMM.
3.
System board assembly.
System board assembly
System board assembly
System board assembly
1. DIMM
2.
System board assembly
1. DIMM
2.
System board assembly
1. DIMM
2.
System board assembly
System board assembly
System board assembly
System board assembly
System board assembly
System board assembly
1. Keyboard
2.
System board assembly
3.
Management module
Intel® Server Compute Blade SBX82: Hardware Maintenance Manual and Troubleshooting Guide
FRU/action