IBM 8832L1X Maintenance And Troubleshooting Manual page 32

Server compute blade
Table of Contents

Advertisement

Table 3. SW4 Light Path Diagnostics LED locations
LED error
NMI
MIS
SBRD
TEMP
Light Path Diagnostics LED
Light Path Diagnostics button (SW4)
See "Diagnosing problems using Light Path Diagnostics" on page 70 for information on what
action to take if there is a component error.
16
Check the error log for additional information. Reboot the
blade server. If the error still exists, replace the system board.
Check the processors to make sure they are at the same
speed.
Reboot the blade server. If the error still exists, replace the
system board.
Check the SBCE unit blowers and air inlets. Check the room
temperature.
Check the Light Path Diagnostics LED for errors
Press SW4 to locate faults on the system board. If the
processor or memory LED is lit, reseat the component. If the
LED remains lit, replace the defective component.
Intel® Server Compute Blade SBX82: Hardware Maintenance Manual and Troubleshooting Guide