IBM 8832L1X Maintenance And Troubleshooting Manual page 119

Server compute blade
Table of Contents

Advertisement

NOTE
See "System" on page 130 to determine which components should be replaced by a field
service technician.
Error code/symptom
062
(Three consecutive startup failures
using the default configuration.)
101, 102
(System and processor error)
106
(System and processor error)
111
(Channel check error)
114
(Adapter read-only memory error)
151
(Real time clock error)
161
(Real time clock battery error)
162
(Device configuration error)
NOTE
Be sure to load the default
settings and any additional
desired settings; then,
.
the configuration
163
(Real-time clock error)
164
(Memory configuration changed.)
165
(Service Processor failure)
184
(Power-on password damaged)
185
(Drive startup sequence information
corrupted)
1. Run the Configuration/Setup Utility program.
2.
Battery.
3.
System board assembly.
4.
Microprocessor.
System board assembly
System board assembly
1. Failing adapter
2.
DIMM
3.
System board assembly
Failing adapter.
1. Battery.
2.
System board assembly.
1. Run the Configuration/Setup Utility program.
2.
Battery.
3.
System board assembly.
1. Run the Configuration/Setup Utility program.
If unable to enter Configuration/Setup Utility program, view
system event log in SBCE management module.
3.
Failing device.
4.
System board assembly.
save
1. Run the Configuration/Setup Utility program.
2.
Battery.
3.
System board assembly.
1. Run the Configuration/Setup Utility program.
2.
DIMM.
3.
System board assembly.
System board assembly
1. Run the Configuration/Setup Utility program.
2.
System board assembly.
1. Run the Configuration/Setup Utility program.
2.
System board assembly.
FRU/action
2.Battery.
103