Scenario 3-1– ProCurve command line configuration
(Multiple Simple Networks Providing Redundancy and Link
Aggregation 802.3ad (LACP))
Connect to the ProCurve switch servicing the VC-Enet uplink ports and enter the following commands.
NOTE: If t w o s w it ch es a r e b ein g u s ed , is s u e t h e s a m e com m a n d s on t h e s econ d s w it ch .
Table 9
Scenario 3-1 - ProCurve command line configuration (untagged VLANs)
Command
>enable
#configure terminal
#span
#trunk 1-2 trk1 lacp
#vlan 1 untagged [Ethernet] trk1
#spanning-tree ethernet trk1 admin-
edge-port
#show vlan ports trk1 detail
#show vlan 1
#write memory
(For permanent changes only)
Shortcut
>en
#conf
#span
#trunk 1-2 trk1 lacp
#vlan 1 untag trk1
#span e trk1 admin-edge
# show vlan ports trk1 detail
#sh vlan 1
#write mem
Appendix B: Scenario-based ProCurve command line reference 222
Description
Privilege mode
Configure in global mode
Enables spanning-tree (MSTP mode
by default)
Configure LACP port-trunk 1 to
include Ports 1 & 2
Allow VLAN 1 on Port 1 & 2 , and
set to untagged mode
Set Port 1 to be an edge port (non
bridging port). Note: port is set by
default in "auto-edge" mode which
automatically sets port to Edge if no
BPDU are received after 3 sec.
Displays the VLAN detail for Trunk 1
Display VLAN 1 port information
Save the running configuration to
NVRAM. Otherwise, the changes
will be lost on the next reboot.