Removing a Line Module, SRP Module, or SRP I/O Module
Copyright © 2010, Juniper Networks, Inc.
NOTE: We recommend that you issue the slot disable command from the
CLI before removing a line module or I/O module.
CAUTION: If you do not use the halt command before removing or powering
down an SRP, the system's NVS card can become corrupted.
To remove a line module, SRP module, or SRP I/O module:
For SRP modules and SRP I/O modules, issue the appropriate halt command (halt,
1.
halt primary-srp, or halt standby-srp).
See JunosE System Basics Configuration Guide, Chapter 6, Managing Modules for
information about the halt commands.
Ground yourself by using an antistatic wrist strap or other device and connect it to the
2.
ESD grounding jack on the chassis.
Use a screwdriver (using a No. 2 Phillips screwdriver, if necessary) to loosen the thumb
3.
screws located at the top and bottom of the module panel.
If the module has ejector handles, pull them to the open position, as shown in Figure
4.
21 on page 42.
Chapter 4: Installing Modules
41