Ct1 And Ce1 I/O Modules - Juniper E SERIES BROADBAND SERVICES ROUTERS 11.3.X - ERX HARDWARE GUIDE REV 26-9-2010 Hardware Manual

E series broadband services routers
Table of Contents

Advertisement

ERX 11.3.x Hardware Guide

CT1 and CE1 I/O Modules

134
Table 21 on page 134 lists the pinout for the straight-through adapter.
Table 21: DB-9—RJ-45 Straight-Through Adapter Pinout
DB-9 Pin
RS-232 Signal Name
1
DCD
2
RXD
3
TXD
4
DTR
5
GND (signal)
6
DSR
7
RTS
8
CTS
9
RNG
CT1 I/O modules have 24 RJ-48C female connectors. CE1 I/O modules have either 20
RJ-48C female connectors or two 25-pair female Telco connectors. Figure 56 on page 134
shows the location of the ports on a CT1 I/O module and the sequence of the pins in the
RJ-48C connector. CE1 I/O modules equipped with RJ-48C connectors have the same
configuration as CT1 I/O modules equipped with RJ-48C connectors.
Figure 56: CT1 I/O Module Ports
Table 22 on page 135 lists the pinout for the CT1/CE1 connector.
RJ-45 Pin
Ethernet Signal Name
1
TX +
2
TX –
3
RX +
4
no connect
5
no connect
6
RX –
7
no connect
8
no connect
no connect
none