Ground yourself by using an antistatic wrist strap or other device and connect it to the
1.
ESD grounding jack on the chassis.
NOTE: See the figures in "ERX Overview" on page 3 for module locations.
Choose the slot in which you want to install the module.
2.
ERX14xx models—Slot 6 or 7
ERX7xx models—Slot 0 or 1
ERX310 router—Slot 0
With a No. 2 Phillips screwdriver, loosen the captive screws that secure the blank filler
3.
panel covering the empty chassis slot, if present, and remove the filler panel.
Remove the SRP module from its antistatic bag, being careful not to touch module
4.
components, pins, leads, or solder connections.
Verify that the ejectors are in the open position, as shown in Figure 20 on page 38.
5.
Figure 20: Ejectors in the Open Position
Slide the module into the chassis by placing it between the guides of the selected slot
6.
and pushing the module until it stops.
The module stops sliding when the ejectors make contact with the front of the chassis.