Snmpv3 Configuration - HP GbE2c - Blc Layer 2/3 Fiber SFP Option Command Reference Manual

Hp gbe2c ethernet blade switch for c-class bladesystem command reference guide
Hide thumbs Also See for GbE2c - Blc Layer 2/3 Fiber SFP Option:
Table of Contents

Advertisement

SNMP parameters that can be modified include:
System name
System location
System contact
Use of the SNMP system authentication trap function
Read community string
Write community string
The following table describes the System SNMP Configuration Menu options.
Table 84
System SNMP Configuration Menu options
Command
snmpv3
name <1-64 characters>
locn <1-64 characters>
cont <1-64 characters>
rcomm <1-32 characters>
wcomm <1-32 characters>
timeout <1-30>
auth disable|enable
linkt <port>
[disable|enable]
ufd
cur

SNMPv3 configuration

Command: /cfg/sys/ssnmp/snmpv3
[SNMPv3 Menu]
usm
view
access
group
comm
taddr
tparam
notify
v1v2
cur
Description
Displays SNMPv3 menu.
Configures the name for the system. The name can have a maximum of 64 characters.
Configures the name of the system location. The location can have a maximum of 64
characters.
Configures the name of the system contact. The contact can have a maximum of 64
characters.
Configures the SNMP read community string. The read community string controls SNMP
"get" access to the switch. It can have a maximum of 32 characters. The default read
community string is public.
Configures the SNMP write community string. The write community string controls SNMP
"set" and "get" access to the switch. It can have a maximum of 32 characters. The
default write community string is private.
Sets the timeout value for the SNMP state machine. The range is 1-30 minutes. The
default value is 5 minutes.
Enables or disables the use of the system authentication trap facility. The default setting
is disabled.
Enables or disables the sending of SNMP link up and link down traps. The default
setting is enabled.
Enables or disables the sending of Uplink Failure Detection traps. The default setting is
disabled.
Displays the current SNMP configuration.
- usmUser Table Menu
- vacmViewTreeFamily Table Menu
- vacmAccess Table Menu
- vacmSecurityToGroup Table Menu
- community Table Menu
- targetAddr Table Menu
- targetParams Table Menu
- notify Table Menu
- Enable/disable V1/V2 access
- Display current SNMPv3 configuration
Configuration Menu 97