View-Based Access Control Model Configuration; Snmpv3 Group Configuration - HP GbE2c - Blc Layer 2/3 Fiber SFP Option Command Reference Manual

Hp gbe2c ethernet blade switch for c-class bladesystem command reference guide
Hide thumbs Also See for GbE2c - Blc Layer 2/3 Fiber SFP Option:
Table of Contents

Advertisement

View-based Access Control Model configuration

Command: /cfg/sys/ssnmp/snmpv3/access
[SNMPv3 vacmAccess 1
name
model
level
rview
wview
nview
del
cur
The view-based Access Control Model defines a set of services that an application can use for checking access rights
of the user. Access control is needed when the user has to process SNMP retrieval or modification request from an
SNMP entity.
The following table describes the User Access Control Configuration Menu options.
Table 88
View-based Access Control Configuration Menu options
Command
name <1-32
characters>
model
usm|snmpv1|snmpv2
level
noAuthNoPriv|authNo
Priv|authPriv
rview <1-32
characters>
wview <1-32
characters>
nview <1-32
characters>
del
cur

SNMPv3 Group configuration

Command: /cfg/sys/ssnmp/snmpv3/group
[SNMPv3 vacmSecurityToGroup 1 Menu]
model
uname
gname
del
cur
Menu]
- Set group name
- Set security model
- Set minimum level of security
- Set read view index
- Set write view index
- Set notify view index
- Delete vacmAccess entry
- Display current vacmAccess configuration
Description
Defines the name of the group, up to a maximum of 32 characters.
Selects the security model to be used.
Defines the minimum level of security required to gain access rights. The level
means that the SNMP message will be sent without authentication and
noAuthNoPriv
without using a privacy protocol. The level
will be sent with authentication but without using a privacy protocol. The
that the SNMP message will be sent both with authentication and using a privacy protocol.
Defines a 32 character long read view name that allows you read access to a particular MIB
view. If the value is empty or if there is no active MIB view having this value then no access is
granted.
Defines a 32 character long write view name that allows you write access to the MIB view. If
the value is empty or if there is no active MIB view having this value then no access is
granted.
Defines a 32 character long notify view name that allows you notify access to the MIB view.
Deletes the View-based Access Control entry.
Displays the View-based Access Control configuration.
- Set security model
- Set USM user name
- Set group name
- Delete vacmSecurityToGroup entry
- Display current vacmSecurityToGroup configuration
means that the SNMP message
authNoPriv
authPriv
Configuration Menu 100
means

Hide quick links: