Electronic Single Point Ignition
Burner Base
Burner Base
Burner Base
Figure 17: STAR® Burner Components
Each STAR® burner has its own electronic igniter that
sparks when the STAR® burner is turned on. Each
STAR® burner should light in 4 seconds or less. If a
STAR® burner does not light, check to see that the
STAR® burner cap is positioned correctly on the base.
CAUTION:
DO NOT touch the STAR® burners when the
igniters are sparking.
If a STAR® burner fails to ignite, refer to "Before Calling For
Service" on page
90.
English 24
Automatic Re-Ignition
If any one or more STAR® burners blow out, the electronic
igniter automatically activates to re-light the flame. DO NOT
touch the STAR® burners when the igniters are active.
IMPORTANT:
Igniter
Igniter
Igniter
Figure 16: Igniter

Power Failure

Burner Cap
Burner Cap
Burner Cap
Igniter
Igniter
Igniter
For proper combustion, DO NOT use the cooktop
without the burner grates in place.
There is a slight sound associated with gas combustion
and ignition. This is normal.
On cooktops using propane (LP) gas, a slight "pop"
sound may be heard at the STAR® burner ports a few
seconds after the STAR® burner has been turned off.
I
n the event of a power failure, only the burners without
ExtraLow® can be manually lit. It is necessary to light
each one individually.
If the cooktop is being used when the power failure
occurs,
turn all knobs to the OFF position.
The Standard
STAR®
burners can be lit by holding a
match at the ports and turning the control knob to the
position. Wait until the flame is burning all around the
STAR®
burner cap before adjusting the
desired level.
The ExtraLow® STAR® burners CANNOT be used
during a power failure. Be sure to turn them off.
If either ExtraLow® STAR® burner is on when a power
failure occurs, they cannot be turned back on until both
knobs are first turned to the OFF position.
The griddle or grill accessory cannot be used during a
power failure.
If you smell gas, refer to safety precautions listed on
page 3.
WARNING:
In the event of a power failure, turn all knobs
to the OFF Position. Only the Standard
STAR® burners can be lit manually.
HI
flame to the

Hide quick links: