Electrical Rating - Thermador PRD48JDSGU Use And Care Manual

Pro grand steam range
Hide thumbs Also See for PRD48JDSGU:
Table of Contents

Advertisement

IMPORTANT:
All ranges must be installed with a back guard. For island
installations and other installations with more than
12" (305 mm) minimum horizontal clearance between
combustible materials and the back edge of the range, a
Flush Island Trim has been supplied with the range. A
THERMADOR® Lowback or Highshelf must be purchased
separately and utilized when there is less than a
12" (305 mm) horizontal clearance.
Before using the range, insure that it is equipped with a
proper back guard. Refer to the Installation Instructions
accompanying this appliance for more information.

Electrical Rating:

240/208 volts, 60 Hz., 50 Amp electrical circuit required.
WARNING:
To avoid possible burn or fire hazard, a back
guard designed specifically for this range
must be installed whenever the range is used.
CAUTION:
The high shelf can get very hot!
DO NOT place the following items on top of
the high shelf:
plastics or containers that can melt
flammable items
a total load over 30 lbs. (13.6 kg).
WARNING:
ALWAYS DISCONNECT THE ELECTRICAL
PLUG FROM THE WALL RECEPTACLE
BEFORE SERVICING THIS UNIT.
It is recommended that a dedicated circuit servicing this
appliance be provided.
The use of gas cooking appliances results in the production
of heat and moisture.
CAUTION:
FOR PERSONAL SAFETY, THIS
APPLIANCE MUST BE CONNECTED TO A
PROPERLY GROUNDED AND POLARIZED
ELECTRICAL POWER SUPPLY.
English 4
See Installation Instructions for electrical requirements and
grounding instructions.
It is the personal responsibility and obligation of you, the
user, to have this appliance connected to the electrical
power supply by a qualified electrician, in accordance with
the National Electrical Code and/or applicable local codes
and ordinances.
WARNING — ALL MODELS:
IN CASE OF AN ELECTRICAL FAILURE
If for any reason a gas control knob is turned
ON and there is no electrical power to operate
the electronic igniters on the range's cooktop
STAR® burners, turn OFF the gas control
knob and wait 5 minutes for the gas to
dissipate before lighting the STAR® burner
manually.
To light the STAR® burners manually,
carefully hold a lighted match to the STAR®
burner ports and turn the gas control knob to
.
HI
During a power
standard cooktop
must be lit with a match.
DO NOT attempt to light the two left XLO®
STAR® burners and two right XLO® STAR®
burners manually. These STAR® burners are
equipped with the ExtraLow® feature and
cannot be lit manually.
TESTED IN ACCORDANCE WITH:
ANSI Z21.1 for Household Gas Appliances
UL858 for Household Electric Ranges
CAN/CSA-22.2 No. 61-M89 for Household Cooking
Ranges
CAN/CGA 1.1-M81 Domestic Gas Ranges
Check your local building codes for the proper method of
installation. In the absence of local codes, this unit should
be installed in accordance with the National Fuel Gas Code
No. Z223.1 current issue and the National Electrical Code
ANSI/NFPA No. 70 current issue or the Can - B149
Installation Codes for Gas Burning Appliances and C22.1
Canadian Electrical Code Part 1.
It is the responsibility of the owner and the installer to
determine if additional requirements and/or standards
apply to specific installations.
failure,
you can use the
STAR®
burners, but each

Hide quick links: