If the Auto Allocation Check Box is selected at this point, the default connections and the parameters
are will be automatically allocated as shown in the following figure.
The following information is displayed in the Register Device List.
Item
Product Name
EPI
Reaction Time
Type
Size
4.
In the Register Device List, you can add and delete connections and edit the connection parameters.
To add a connection, select the Safety Slave that you want to add the connection to and click the
New Button. Refer to 5-1-2 Setting Safety Connection Parameters (page 82) to set the parameters.
To delete a connection, select the connection you want to delete and click the Delete Button.
To edit connection parameters, select the connection you want to edit and click the Edit Button.
The parameters of the selected connection will be displayed. Refer to 5-1-2 Setting Safety Connec-
tion Parameters (page 82) to change the parameters.
Select the Safety Slave and click the Register/Unregister Button. If connections are already set,
the button cancels all the connections and if not, it allocates the default connection and parameters.
Note: – To delete a Safety Slave from the Register Device List, select the Safety Slave you want to delete
and click the Button.
– Also, when either of the following operations is performed in the Network Configuration Window,
the Safety Slave will be registered using auto-allocation.
(1) Dragging a slave device to the NE1A-SCPU01.
(2) Selecting a slave device and specifying the destination as the NE1A-SCPU01 by selecting
IMPORTANT:
5-1 Safety Connection Settings
Information displayed
The name of the registered Safety Slave (
connection (
icon) is displayed.
The EPI for the safety connection is displayed. For details on EPI, refer to 5-1-
2 Setting Safety Connection Parameters (page 82).
The network reaction time for the safety connection is displayed.
The type of the I/O assembly used in the safety connection is displayed.
The data size of the I/O assembly used in the safety connection is displayed.
Device and then Register to Other Device from the menu bar.
Changing safety connection settings may affect the program. After changing any setting,
always open the Logic Editor and check the program.
icon) or I/O assembly used in the safety