Click the Comment Tab to enter names for the function block or I/O signals. The names of I/O signals are
not displayed in the window, but the name of the function block is displayed under the function block in the
window. All the names entered in this window, however, are printed when the program is printed.
Sending Explicit Messages
An explicit message can be set in advance and then sent when an output tag turns ON as a trigger. One
explicit message can be set for the entire program. Select Function - User EM from the menu bar.
Trigger Address
Select the output tag to function as the trigger for sending the explicit message. Every time the specified out-
put tag changes from OFF to ON, the explicit message set as the send message will be sent.
Retry Count
Set the number times sending will be retried if explicit message transmission fails.
Set to 0 for no retries.