Omron DEVICENET SAFETY - CONFIGURATION MANUAL 05-2005 System Configuration Manual page 116

Devicenet safety system
Table of Contents

Advertisement

(3) Right-click the NE1A-SCPU01 and select Monitor from the pop-up menu. Click the Safety Connection
Tab in the displayed window.
The connection status of the Safety Slave is displayed for the local node address. For the other node ad-
dresses, the statuses of the safety connections configured for the device parameters are displayed.
Device Status
The connection status can be checked for each node address in the Device Status Field. The connection
status is indicated by the following colors.
Color
Gray
Green
Blue
Yellow
Red
For the local node address (i.e., the node address of the Safety Slave), the color gray indicates that there are
no connections or that an error has occurred in a connection. The color blue indicates that normal commu-
nications are being performed in one or more connections.
Connection Status
The status can be checked for each safety connection in the Connection Status Field. The connection status
is indicated by the following colors.
Color
Gray
Green
Blue
Red
For the local node address (i.e., the node address of the Safety Slave), the color gray indicates that there is
no connection or that an error has occurred in the connection. The color blue indicates normal communica-
tions.
114
Status
Unregistered device.
All the connections are sending idle data.
All the connections are communicating normally.
At least one connection is not connected or sending idle data. (An error has occurred and
there is no connection.)
An error has occurred in at least one connection.
Status
Connection is not connected.
Idle data is being transmitted.
Normal communications are being performed.
Connection error has occurred.
Section 7: Monitoring Devices