Setting Memory Blocks for Allocation
1.
Select a master and then select Device - Parameter - Edit. The Edit Device Parameter Dialog Box will
be displayed.
2.
Click the I/O Allocation (OUT) Tab.
3.
Click the Setup... Button in the Memory Block 1 Area.
4.
Set the Area, Start Word, and Display Words (i.e., the number of words in) for Memory Block 1.
5.
Set Memory Block 2 in the same way.
6.
Click the I/O Allocation (IN) Tab and set the Memory Blocks in the same way as the OUT block.
Note: – Set the Area setting for unused blocks to Not Use.
– The number of displayed words is the number of words of a block displayed in the Network Config-
urator. This value is not downloaded to the Unit.If the allocated area in a block is 100 words or less
when uploaded, the number of displayed words will be set to 100 and displayed.
Specifying Auto-allocation at Registration
If the option for auto-allocation (Auto-allocation as is registered) is selected, words will be allocated for I/
O automatically in the order of registration when slaves are registered to a master in the Edit Device
Parameters Window. This option is effective only in the Edit Device Parameters Window.
Auto-allocation allocates words starting from unused words in Block 1 of the corresponding I/O memory
block in the order of registration (i.e., in the order slaves are dropped).
Deleting or changing I/O allocations for the selected slaves (allocating unused word) can be performed
anytime by clicking the Auto Register/Unregister Button.
146