Material Usage Key 4, Level 6

Level Sensor Selection

Default Setting: 1
Purpose
To set the control to monitor reservoir low and or full
level sensors, and activate feed pumps and alarms if
feed pumps are used. The standard system comes
with level sensors, installed in the lower reservoir
port.
Access
In setup level 6, press key 4 on the keypad to access
the Level Sensor Selection function.
Keypad Display
The key 4 light is green and 6 appears in the keypad
setup level position. See Fig. 72.
System Schematic Panel
The level sensor lights will blink for the sensors that
have been activated. The default setting display is
shown in Fig. 73.
Changing Values
Press an arrow key until the number for the desired
Level Sensor setting displays.
0
Deactivates level sensors.
Set to 0 when priming the pump or flushing.
CAUTION
The 0 setting is to be used only for special cases
such as system flushing and color change when
close supervision is possible and minimizing the
volume of material in the reservoir is desirable.
1
Low level sensors only; no feed pumps.
Sets the control to only monitor the Low Level
Sensor, disables the feed pump alarms, and
disables the feed pump keys on the system
schematic panel.
2
High level sensors only; with feed pumps.
Sets the control to only monitor the Full Level
Sensor (used to turn feed pumps on and off),
enables the feed pump alarms, and enables
the feed pump keys on the system schematic
panel.
Setup Functions
Fig. 72
Fig. 73
Material Usage Key 4, Level 7

Number of Software Startups

Purpose
To display the number of times the SuperCat propor-
tioner has been powered up.
Fig. 74
4
Default Setting Display
A
B
A B
3
Both sensors; no feed pumps.
Sets the control to monitor both the Full Level
and Low Level Sensors and disables the feed
pumps and alarms.
4
Both sensors; with feed pumps.
Sets the control to monitor both the Full Level
and Low Level Sensors (used to turn feed
pumps on and off), enables the feed pump and
low level alarms, and enables the feed pump
keys on the system schematic panel.
4
A/B S
A
A/B
S
B
B AB
A
A
B