Material B Usage - Graco SuperCat 232096 Instruction Manual

Proportioner packag
Table of Contents

Advertisement

Material Usage Key 4, Level 2

Material B Usage

Default Setting: see chart below for default settings
depending on the pump ratio
Purpose
To set the cycles per gallon/liter for proportioner side
B. This allows the multiplier to calculate the usage of
material B.
Access
In setup level 2, press key 4 on the keypad to access
the Material B Usage function.
Keypad Display
The key 4 light is green and 2 appears in the keypad
setup level position. See Fig. 64.
System Schematic Panel
The pump B light blinks. See Fig. 65.
Changing Values
See the chart below for settings for the fixed ratio
pumps.
Press the arrow keys to change the cycles per gallon/
liter for proportioner side B.
Fixed
Dura-Flo
Ratio
Pump
Model
(Side B)
2:1
1200
3:1
600
4:1
600
WARNING
COMPONENT RUPTURE HAZARD
Do not exceed the 5000 psi (34 MPa,
345 bar) Maximum Working Fluid Pres-
sure of the system. Over-pressurizing
can rupture components and cause
serious injury.
Setup Functions
Cycles/
Cycles/
Gallon
Liter
25
3.3
50
13.2
50
13.2
Fig. 64
A
B
A B
Fig. 65
4
Material B Usage
A/B S
A/B
S
A
B
B AB
A
A
B

Advertisement

Table of Contents
loading

Table of Contents