Minolta 9000 Service Manual page 215

Hide thumbs Also See for 9000:
Table of Contents

Advertisement

Switch
Judgment
Sw. PV1
Should be ON by sliding PV lever.
Should be OFF by releasing PV lever.
Release shutter in "bulb" setting.
Should be ON when Ist shutter blade has
Sw.X
run completely.
Should be OFF when 2nd shutter blade
has run completely.
% DO NOT SET DC-POWER-SUPPLY AT VOLTAGE MOI
damaged.
3. DC/DC
converter
it with DC power supply.
'AF coupler
slowly with finger :
Pointer of circuit tester should move.
RE THAN 12V: otherwise LED will be
Check voltage between printed wires
shown in the figure and GND. (Sw. 1 ON)
Vee2
13V
|
_vooo
av
Veo 1
BV
68