Servicing measures against "in-finder segments OFF"
1. Unjoin flex PCB-A and LCD;.
1) Unhook @ (right and left) of in-finder pressure plate-B (2072-5072). Remove in-finder pressure
plate-A (2072-50741. Light shield tape is unnecessary
more.
2) Strip off flex PCB-A in the direction of arrow. bolding around B of flex PCB-A.
(Be careful not to seratch printed wire of flex PCB-A.)
Fig. 1
3 Wipe off coating © between LCD: and flex PCB-A with using Fronsolve. See fig. 2.)
© Be careful not to scratch printed wire of flex PCB-A.
@ Wipe off coating thoroughfully
&
© Be careful nat to flow Fronsuive in between LCD; 2071-4246-01 and incfinder prism '2072.
5815-02,.
4) Turn inefinder set upside down, and reinforce mirror with B-60 Bond G-17) or B-30 |Araldite).
Fig. 2
+ Re-join of flex PCB-A and LCD;
1) Replace in-finder pressure-C 2072-5073.01 by -81. See fig. 3
Fig. 3
2072-5073-81