Minolta 9000 Service Manual page 229

Hide thumbs Also See for 9000:
Table of Contents

Advertisement

teem
Checking part
Description
Exposure
Lep
'©(With frame counter showing number ; ie. except "S", "®")
adjustment
LCD should display as follows when depressing exposure-adjustment key :
(On body
In viewfinder
3
F.B_}
wen exsosure acustment is 0
'@Each time S-up/-down lever is depressed with exposure-adjustment key held
down, indication of exposure-adjustment should change by 0.5EV.
When the key is held down, the indication should change up/down to +4Ev
continuously.
AE lock
[AE lock button | Operation----Should have proper click,
Lep
(ln PA. S modes)
Press and hold AE lock button : the measurement (when AE is locked) should
be held.
lla PALS modes)
Start selfstimer with AE lock button held down : the measurement (when AE
1s locked) should be held until shutter-release even if AE lock button is
unlocked.
Shutter
Operating
Should be free from catching. roughness. looseness, Should have proper click.
'operation
button
Shutter blade | Should be free from stain, uneven surface. Shutter opening/closing should be
'smooth and complete*.
% ! Check opening in slow shutter speed (1/60 or slower) setting. 1st and
2nd shutter blades should aot be in sight while shutter opens. 2nd
shutter-blades should not hit Ist shutter-blade:
Self-timer
Vith selfotimer start, self-timer LED should blink in the following cycle:
With main switch ))) . camera should beep simultaneously.
10-080,
ie
svat
snout
Start
Release
©Self-timer activation should be canceled by depressing film-speed key or
exposure-adjustment key, or by sliding down preview switch button.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alpha 9000Maxxum 90002071-2002071-4002071-600

Table of Contents