Check 1]
With mirror up, press ® (fig. 2). Disengaging @ of mirror-up sub-lever should require 160g (max).
(Check w/ fig.3 © disengaged.)
Check [2]
With mirror up, press @ \fig.2). Disengaging @, ® (fig.2, 3) should require 200g (max).
Check
With aperture control set itself, press ® (fig. 3). Disengaging ® should require
100g (max!
MFig.2
Mrrorso sub-lever
Lar renew set
®
024 Rerun stop lever
0203