No. 2071-001,
I"AE
adjusting" (Repair Guide p. 32) will be modi:
because
of modification
of IC,.
ied partly
'As a servicing part, flex PCB-A set (2071-0401-01) with new IC, will be supplied after running out of
that with previous IC,
To distinguish new IC, from previous one, see the number (*1) printed on IC;
Previous IC, : MS0755-903
New IC,
MSQ755-907
HAE adjusting
Measuring instruments : Camera I/O tester (MODEL 10-5101)
{
Master lens (2072.0001-75)
+ Luminance source (MODEL L-2101, L-222, L-223)
Adjusting procedure
1, Set camera and measuring instruments as below :
Fig. 1
Lumoance source
'* Luminance source
*Camera
170 taster
K vale
313
Iso
100
DC-OUT : 3V
LuminanceEv 10 (Ev 11+ND 50%)*
Exposure mode | A
Metering mode : See below
Aperture
35.8
Focus mode:
M
3: Luminance in perentheses show the case of using luminance source L-222 or L-223.
2. Release the shutter until frame counter shows "1".
3. Push [7] key and then [ENT] key of camera I/O tester.
Ts be continued on next page.