Block assembling
n
Measuring instruments, Tools, Subsidiary materials
@ Precautions
Wi The following precautions must be taken concerning all plastic parts,
1, When cleaning. use Flonsolve or alcohol. Do not use thinner, ketone, ether etc.
2. Secure all parts with the specitied screws.
taking care not to exert excessive stress to them.
Handling of the Flexible PC board
The flexible PC board uses MOS ICs and is very sensitive to static electricity. Therefore, the following
points must be kept in mind when repairing
'@ When handling the flexible PC board itself or wiring it to the body, use a conductive mat to prevent
Static electricity, and pertorm all work as shown below.
Touch the conducte mat with your
ikon