CHECK
LIST
1. This check list shows the allowable quality level for servicing so as to warrant product quality to the users of Minolta
cameras. Each item is detailed so that you can use this check list to meet the user's requirements. Also, use this to
recheck the repaired camera before returning it to the user.
2 When delivery oF acceptance inspections are required, however, do not directly apply this check list to check the result
of actual measurement, but follow the acceptance check list (manual) involved after grasp the meaning of inspection
purpose correctly.
3, Because of user's taste or special purposes, they may sometimes require standards other than this
In that case, check if it is possible to meet the user's request, and perform the necessary adjustment.
4, Check under the following. conditions :
'Standard lens (2550-100) or master lens (2072-0001-75) attached.
'Main switch ON oF 9))) _, initiatloading completed, metering mode
; AVERAGE.
'Exclusive flash
: 2800AF (8821).
In this Check List, example of LCD display is shutter speed of 1/250, aperture of 1/56.
item
Checking part
Description
Power ON/hold | Main switch
| Operation-~--Should be free from squeak, roughness.
'Should have proper click
\Next letters should not be visible at click position.
Buzzer-Should beep under following conditions in «))) position :
Infocus signal (green LED) ON with focus mode AF.
metering switeh ON.
Infocus signal (green LED) ON with focus mode M, touch switch
ON.
Touch switch | By touching operating button, circuits (metering, indication, AF* should be
activated, measurement should be displayed, and continuous AF should start.
% ' focus-assist circuit with focus mode in M.
Metering switch | By depressing operating button to the click stop, circuits (meteri
indication AF* should be activated, measurement should be displayed, and
foeus should be held.
circuit with focus mode in M.
9 5 focus-as:
© By operating switch', circuits (metering, indication' should be activated.
By turning the switch" OFF, power-ON should be held for 10 sec.
MS touch switch, metering switch, film-speed key. exposure adjustment key.
AE lock button,
© During metering activation, power-ON should be held for 10 sec after
depressing S-up/-down lever or A-up/-down lever.
© After APO (auto power off) circuit activation with exclusive flash used,
flash should be re-charged by touch switch (or metering switch) ON.
Stand-by display-~--By t u r n i n g
main switch ON-or @))) . body LCD should
show the following stand-by display :
Body LCD
Winding
Film advance | Oper:
'Should be free from unsmoothness, roughness, catching.
Looseness---Should be less than O-7mm when measured at the tip of the
lever.
[Note] In this Check List, "S-up/-down lever'
aperture up/down control lever.
is for shutter up/down control lever, and "A-up/-down lever" is for