Minolta 9000 Service Manual page 98

Hide thumbs Also See for 9000:
Table of Contents

Advertisement

27
Wi Finder back adjusting
MBefore adjusting, never fail to attach TYPE PM focusing screen (2072-8231-310).
MiMeasuring instruments : 1000mm collimator (MODEL RC-1000 I, M1, Ml)
: Master lens (20720001-75)
1 Magnifier
2 VB adjuster (2071-5147-75)
HlAdjusting procedure
1, Set the camera so that chart image is shown in the center of finder, and set the focusing lens of
master lens to infinity (00).
MFig. 1
'TYPE PM focusing screen
MFig. 2
We asuster
2O7-S147-75
{
© Adjust finder back, holding mirror with finger as Fig. 2.
times, chart image should be in focus at infinity (20).