34
@ Strobo level adjusting
lAdjusting by luminance source (MODEL L-2101)
The MODEL
L-2101 luminance box should be used. However, ones with color temperatures ranging from
2600K
to 3000K (measured value of the Minolta color meter) at EV 15 can also be used.
'@ Luminance boxes with long-wavelength cut
filters and lamps with cold mirrors cannot be used because of
measuring errors. (Example : MODEL L-223)
@ When no luminance source is used for the adjustment, employ method B on the next page.
[Measuring instruments : Luminance source (MODEL L-2101)
1 Strobo level adjuster (2017-0001-75)
! Film (Use Kodacolor VR 100 which has been exposed to indoor light at
least one day.)
+ Master lens (2072-0001-75)
: DC power supply (MODEL 524B, E-1, E:2)
= Time counter (MODEL TC-1
ST-53101 is usable.
HAdjusting procedure
1, Set camera and measuring instruments as below:
Tana
2017-0001+ 75,
Metering mode > AVERAGE
Mode
ra
fen ee
so
5100
Luminance source
Aperture
3.6
=
Luminance source
=
Luminaner © EV 15
=
«
K value
13
=
I f
Time counter
=
-
Trigger slope A-CH { =
aci
Trigger level A-CH :
BCH
2. Release the shutter until frame counter shows "1".
3. With the shutter celeased, adjust by turning VR3 so that indicatiun of time counter is in 0.84
O.Lms.