Minolta 9000 Service Manual page 97

Hide thumbs Also See for 9000:
Table of Contents

Advertisement

26
i Body back adjusting
MiMeasuring
instruments : Body back gauge
Flat plate (for 2005)
Dial gauge
1 Adjusting back cover (2071-1101-75)
Adjusting procedure
1. Install adjusting back cover, release the shutter until frame counter shows "!
2, Measure and adjust body back (Standard) "[44,70=0.Olmm
X# {Required correction of dial gauge by Imm as figure below since body back gauge is based on
conventional
SLR cameras such as X-700 whose reference value of body back is 43.70mm.
'@Note : One scale for short indicator of dial gauge shows
Imm.
43,7000
ef the body back is lower than the standard valve, insert adjusting washers under the bayonet mount.
[Types of adjusting washers}
2005-1061-81 | 2005-1062-81 | 2008-1063-81
Parts No.
Tisiness | oe
ot