15. Pass the key counter electrical wires
through the edging.
16. Connect the connector of the key
counter electrical wires to the connector
of the option PWB.
17. Fit the scanner rear cover using two
screws.
18. Fit the right upper cover.
Note: Pass the connector of the key
counter wire through the aperture (right
side) in the right upper cover.
Note: Be careful not to put a key coun-
ter electric wire with the upper right
cover.
19. Fit the scanner right cover using two
screws.
20. Insert the projection of the key counter
cover retainer in the aperture of the
right upper cover.
21. Fit the key counter cover retainer using
the two M4 x 10 screws.
Service Manual
Wire saddle C
Edging
Connector
Figure 1-2-26
Aperture
M4x10 screw
Figure 1-2-27
1-2-22
Key counter
electrical wires