Download Print this page

Olivetti d-Color MF2552 plus Service Manual page 236

Multifuction digital copier

Advertisement

Item No.
U464
Method: [Calib]
1. Select the item to be set
2. Press the start key. The operation starts.
Regist
Gamma
Paper Int
Color Regist
3. To stop operation, press the stop key.
Method: [FM Calib]
1. Select the item to be set
2. Press the start key.
On
Off
Initial setting: Off
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U467
Setting the color registration adjustment
Description
Sets the color registration adjustment.
Purpose
If color variance is uneven due to a sensor failure, etc., turn this off and temporarily make a man-
ual adjustment.
Method
1. Press the start key.
2. Select the item to be set.
Permission
Timing
Setting
1. Change the setting value using the +/- keys or numeric keys.
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Service Manual
Display
Executes the calibration to correct registration.
Executes the calibration to quantities of light.
Executes the calibration between paper.
Executes the calibration to color registration.
Display
FM calibration is included in a calibration.
FM calibration is not included in a calibration.
Display
Setting of operation permission
Setting of execution timing of resist correction
Description
Description
Description
Description
1-3-150
2NP
Y116141-8

Advertisement

loading