Download Print this page

Olivetti d-Color MF2552 plus Service Manual page 437

Multifuction digital copier

Advertisement

When connecting the USB cables (YC21, YC22, YC26) to the PWB, connect to the connectors which the
cable length match.
(Connecting to any connector is satisfactory.)
YC26
YC22
Detaching of EEPROM
1. The flat screwdriver is inserted between
EEPROM and socket.
2. Detach it little by little right and left and
alternately while noting the
transformation and the damage of the
pin.
Y116141-8
YC21
Figure 1-5-63
1-5-35
EEPROM
Soket
Flatscrew driver
Figure 1-5-64
2NP
Main PWB
Service Manual