1-5-8 Drive section
(1) Detaching and refitting the drive unit 1
Procedure
1. Remove the rear cover.
(See page 1-5-4)
2. Remove the connector.
3. Remove four screws and then remove
the drive unit 1.
4. Check or replace the drive unit 1 and
refit all the removed parts.
NOTE: When refitting the drive unit 1, checks
that the position of a cam is in the A side from
the upper limit line.
NOTE: When cam isn't in the A side from the
upper limit line, turn the motor by hand and
bring the cam into the A side.
Service Manual
Drive unit 1
Screw
Screw
Screw
Screw
Drive unit 1
1-5-18
Connector
Drive unit 1
Figure 1-5-32
Motor
Upper limit line
Figure 1-5-33
2NP
Hooks
A
Cam
Y116141-8