Download Print this page

Olivetti d-Color MF2552 plus Service Manual page 228

Multifuction digital copier

Advertisement

Item No.
U425
Setting the target
Description
Enters the lab values that is indicated of the chart 1 (P/N: AVGR14938B) or chart 2
(P/N: AVGR05131K) used for adjustment.
Purpose
Performs data input in order to correct for differences in originals during automatic adjustment.
Method
1. Press the start key.
2. Select the chart to be used.
Chart1
Chart2
Method: [Chart1]
1. Press the start key.
2. Select the item to be set.
White
Black
Gray1
Gray2
Gray3
C
M
Y
R
G
B
Adjust Original
3. Select the item to be set.
L
a
b
4. Enters the value that is indicated on the face of the chart using the +/- keys or numeric keys.
5. Press the start key. The value is set.
Service Manual
Display
Chart 1 (P/N: AVGR14938B)
Chart 2 (P/N: AVGR05131K)
Display
Setting the white patch for the original for adjustment
Setting the black patch for the original for adjustment
Setting the Gray1 patch for the original for adjustment
Setting the Gray2 patch for the original for adjustment
Setting the Gray3 patch for the original for adjustment
Setting the cyan patch for the original for adjustment
Setting the magenta patch for the original for adjustment
Setting the yellow patch for the original for adjustment
Setting the red patch for the original for adjustment
Setting the green patch for the original for adjustment
Setting the blue patch for the original for adjustment
Setting the main and auxiliary scanning directions
Display
Setting the L value
Setting the a value
Setting the b value
Description
Description
Description
Description
1-3-142
Setting range
0.0 to 100.0
-200.0 to 200.0
-200.0 to 200.0
2NP