Wiring - Omron SYSDRIVE RV Series User Manual

High-function general-purpose inverters
Table of Contents

Advertisement

Wiring

Wiring examples are provided in the following illustrations for the Control Cards.
Wiring the 3G3FV-PPGA2
Wiring examples are provided in the following illustrations for the 3G3FV-PPGA2.
-38
2
Inverter
Three-phase, 200
VAC (400 VAC)
R/L1
V/T2
W/T3
Fig 2.27 Wiring a 12-V Voltage Input
Three-phase,
Inverter
200 VAC (400 VAC)
R/L1
U/T1
V/T2
V/T2
W/T3
W/T3
4CN
Shielded twisted-pair wires must be used for signal lines.
Do not use the pulse generator's power supply for anything other than the pulse generator (encoder).
Using it for another purpose can cause malfunctions due to noise.
The length of the pulse generator's wiring must not be more than 30 meters.
Fig 2.28 Wiring an Open-collector Input
U/T1
V/T2
W/T3
3G3FV-PPGA2
+12 V power supply
1
0 V power supply
2
4CN
4CN
3
4
12 V voltage input (A/B phase)
TA1
5
Pulse 0 V
6
E
E
7
TA2 (E)
8
3G3FV-PPGA2
+12 V power supply
1
0 V power supply
2
4CN
3
4
TA1
Open collector output (A/B phase)
5
Pulse 0 V
6
E
E
7
TA2 (E)
8
E6B2-CWZ3E
Pulse monitor output
E6B2-CWZ6C
Pulse monitor output

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

3g3rv-v1

Table of Contents