Analog Reference Board: F2
User parameters for the Analog Reference Board are shown in the following table.
Name
Param-
eter
Number
Display
Sets the functions for chan-
nel 1 to 3 which are effective
Bi-polar or
when the 3G3IV-PAI14B
uni-polar
Analog Reference Board is
input selec-
used.
tion
0: 3-channel individual
(Channel 1: terminal A1,
Channel 2: terminal A2,
F2-01
Channel 3: terminal A3)
1: 3-channel addition (Addi-
tion values are the fre-
quency reference)
AI-14 Input
When set to 0, select 1 for
Sel
b1-01. In this case the multi-
function input "Option/
Inverter selection" cannot be
used.
Digital Reference Board: F3
User parameters for the Digital Reference Board are shown in the following table.
Name
Param-
eter
Number
Display
Sets the Digital Reference
Board input method.
0: BCD 1% unit
1: BCD 0.1% unit
Digital
2: BCD 0.01% unit
input option
3: BCD 1 Hz unit
4: BCD 0.1 Hz unit
5: BCD 0.01 Hz unit
F3-01
6: BCD special setting (5-
digit input)
7: Binary input
6 is only effective when the
3G3IV-PDI16H2 is used.
DI Input
When o1-03 is set to 2 or
higher, the input will be
BCD, and the units will
change to the o1-03 setting.
Setting
Description
Range
0 or 1
Setting
Description
Range
0 to 7
Control Methods
Change
Factory
during
V/f
Open
Setting
Opera-
V/f
with
Loop
tion
PG
Vector
0
No
A
A
Control Methods
Change
Factory
during
V/f
Open
Setting
Opera-
V/f
with
Loop
tion
PG
Vector
0
No
A
A
User Parameter Tables
Regis-
Flux
Page
ter
Vec-
tor
A
A
38FH 6-197
Regis-
Flux
Page
ter
Vec-
tor
A
A
390H 6-198
5-