Related Parameters
Param-
eter
Number
Parameter
access level
A1-01
Access
Level
Password
A1-04
Enter Pass-
word
Password
setting
A1-05
Select Pass-
word
Setting Precautions
Parameter A1-05 cannot be displayed using normal key operations. To display A1-05, hold down the RESET
Key and press the MENU Key while A1-04 is displayed.
-190
6
Name
Description
Display
Used to set the parameter
access level (set/read.)
0: Monitoring only
(Monitoring drive mode
and setting A1-01 and
A1-04.)
1: Used to select user
parameter
(Only parameters set in
A2-01 to A2-32 can be
read and set.)
2: Advanced
(Parameters can be read
and set in both quick
programming mode and
advanced programming
(A) mode.)
Password input when a pass-
word has been set in A1-05.
This function write-protects
some parameters of the ini-
tialize mode.
If the password is changed,
A1-01 to A1-03 and A2-01
to A2-32 parameters can no
longer be changed. (Pro-
gramming mode parameters
can be changed.)
Used to set a four digit num-
ber as the password.
This parameter is not usually
displayed. When the Pass-
word (A1-04) is displayed,
hold down the RESET Key
and press the Menu Key and
the password will be dis-
played.
Control Methods
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0 to 2
2
Yes
A
0 to
0
No
A
9999
0 to
0
No
A
9999
Regis-
V/f
Open
Flux
ter
with
Loop
Vec-
PG
Vector
tor
A
A
A
101H
A
A
A
104H
A
A
A
105H