Omron SYSDRIVE RV Series User Manual page 401

High-function general-purpose inverters
Table of Contents

Advertisement

Name
Param-
Description
eter
Display
Number
Sets the stopping method
when a speed deviation
(DEV) fault occurs.
Operation
0: Ramp to stop
selection at
(Deceleration stop using
deviation
Deceleration Time 1, C1-
02.)
F1-04
1: Coast to stop
2: Fast stop (Emergency
stop using the
deceleration time in C1-
PG Devia-
09.)
tion Sel
3: Continue operation (DEV
is displayed and
operation continued.)
0: Phase A leads with For-
ward Run Command.
PG rotation
(Phase B leads with
Reverse Run Command.)
F1-05
1: Phase B leads with For-
ward Run Command.
PG Rota-
(Phase A leads with
tion Sel
Reverse Run Command.)
Sets the division ratio for the
PG division
PG speed control board
rate (PG
pulse output.
pulse moni-
Division ratio = (1+ n) /m
tor)
(n=0 or 1 m=1 to 32)
F1-06
F1-06
This parameter is only effec-
tive when a 3G3FV-PPGB2
PG Output
is used.
Ratio
The possible division ratio
settings are: 1/32 ≤ F1-06 ≤
1.
Integral
Sets integral control during
value during
acceleration/deceleration to
accel/decel
either enabled or disabled.
enable/dis-
0: Disabled (The integral
able
function isn't used while
F1-07
accelerating or
decelerating; it is used at
parameter speeds.)
PG Ramp
1: Enabled (The integral
PI/I Sel
function is used at all
times.)
Setting
Factory
Range
Setting
0 to 3
0 or 1
1 to
n
m
132
0 or 1
Control Methods
Change
during
V/f
Open
Opera-
V/f
with
Loop
tion
PG
Vector
3
No
No
A
No
0
No
No
A
No
1
No
No
A
No
0
No
No
A
No
Options
Regis-
Flux
ter
Vec-
tor
A
383H
A
384H
A
385H
No
386H
193
6-