Omron SYSDRIVE RV Series User Manual page 61

High-function general-purpose inverters
Table of Contents

Advertisement

Connecting the Braking Resistor (Mounting 3G3IV-PERF)
A Braking Resistor that mounts to the Inverter can be used with 200-V and 400-V Class Inverters with outputs
from 0.4 to 37 kW.
Connect the braking resistor as shown in Fig 2.15.
L8-01 (Protect selection for internal DB resistor)
L3-04 (Stall prevention selection during deceleration)
(Select either one of them.)
The braking resistor connection terminals are B1 and B2. Do not connect to any other terminals. Connecting
to any terminals other than B1 or B2 can cause the resistor to overheat, resulting in damage to the equip-
ment.
IMPORTANT
Connecting the Braking Resistor Unit (3G3IV-PLKB ) and Braking Unit (3G3IV-
PCDBR )
Connect the Braking Resistor Unit and Braking Unit to the Inverter as shown in the Fig 2.15.
A Braking Resistor that mounts to the Inverter can also be used with Inverters with outputs from 0.4 to 3.7
kW.
L8-01 (Protect selection for internal DB resistor)
L3-04 (Stall prevention selection during deceleration)
(Select either one of them.)
L8-01 is used when a braking resistor without thermal overload relay trip contacts (3G3IV-PERF
to Inverter) is connected.
The Braking Resistor Unit cannot be used and the deceleration time cannot be shortened by the Inverter if L3-
04 is set to 1 (i.e., if stall prevention is enabled for deceleration).
Table 2.9
1 (Enables overheat protection)
0 (Disables stall prevention function)
3 (Enables stall prevention function with braking resistor)
Inverter
Fig 2.15 Connecting the Braking Resistor
Table 2.10
0 (Disables overheat protection)
0 (Disables stall prevention function)
3 (Enables stall prevention function with braking resistor)
Wiring Main Circuit Terminals
Braking resistor
mounted
23