Accelerating And Decelerating Constant Frequencies In The Analog References (+/- Speed) - Omron SYSDRIVE RV Series User Manual

High-function general-purpose inverters
Table of Contents

Advertisement

Accelerating and Decelerating Constant Frequencies in the Analog Refer-
ences (+/- Speed)
The +/− speed function increments or decrements the frequency set in analog frequency reference d4-02 (+/−
Speed Limit) using two contact signal inputs.
To use this function, set One of the parameters H1-01 to H1-06 (multi-function contact terminal inputs S3 to
S8 function selection) to 1C (Trim Control Increase command) and 1D (Trim Control Decrease command). Be
sure to allocate two terminals so that the Trim Control Increase command and Trim Control Decrease com-
mand can be used as a pair.
Related Parameters
Name
Param-
eter
Display
Number
Set the frequency to be add
to or subtracted from the
+ − Speed
analog frequency reference
limits
as a percent, taking the max-
imum output frequency to be
d4-02
100%.
Enabled when the increase
(+) speed command or
Trim Con-
decrease (−) speed command
trol Lvl
is set for a multi-function
input.
Trim Control Increase/Decrease Command and Frequency Reference
The frequency references using Trim Control Increase/Decrease command ON/OFF operations are shown
below.
Frequency Reference
Trim Control Increase
Command Terminal
Trim Control Decrease
Command Terminal
Application Precautions
Trim Control Increase/Decrease command is enabled when speed reference > 0 and the speed reference is
from an analog input.
When the analog frequency reference value − d4-02 < 0, the frequency reference is set to 0.
The value of the auxiliary speed-frequency reference is incremented or decremented by the value of the
master speed-frequency reference ± d4-02.
If only the Trim Control Increase command or Trim Control Decrease command has been set for a multi-
function contact input terminal S3 to S8, operation error OPE03 (invalid multi-function input selected)
will occur.
Setting
Description
Range
0 to
100
Set Frequency
Set Frequency
Reference
Reference
+ d4-02
− d4-02
ON
OFF
OFF
ON
Input Terminal Functions
Control Methods
Change
Factory
during
V/f
Open
Setting
Opera-
V/f
with
Loop
tion
PG
Vector
10%
No
A
A
Set Frequency Command
ON
ON
Regis-
Flux
ter
Vec-
tor
A
A
299H
OFF
OFF
6-
87

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

3g3rv-v1

Table of Contents