Setting Parameters
Here, the procedure is shown to change C1-01 (Acceleration Time 1) from 10 s to 20 s.
Step
No.
1
2
3
4
5
6
7
8
9
10
11
-10
3
Table 3.4 Setting Parameters in Advanced Programming Mode
Digital Operator Display
Description
Power supply turned ON.
MENU Key pressed to enter Drive Mode.
MENU Key pressed to enter Quick Program-
ming Mode.
MENU Key pressed to Enter Advanced Pro-
gramming Mode.
ENTER pressed to access monitor display.
Increment or Decrement Key pressed to dis-
play C1-01 (Acceleration Time 1).
ENTER Key pressed to access setting display.
The setting of C1-01 (10.00) is displayed.
Digit Selection/RESET Key pressed to move
the flashing digit to the right.
Increment Key pressed to change set value to
20.00 s.
ENTER Key pressed to enter the set data.
"END" is displayed for 10 s and then the
entered value is displayed for 0.5 s.
The monitor display for C1-01 returns.