Sets motor mechanical loss
as a percentage of motor
Motor
rated output (W).
mechanical
Usually setting is not neces-
loss
sary.
Adjust in the following cir-
E2-09
cumstances:
• When torque loss is large
due to motor bearing.
Mechanical
• When the torque loss in
Loss
the pump or fan is large.
The set mechanical loss will
compensate for torque.
Motor iron
loss for
torque com-
Sets motor iron loss in W
E2-10
pensation
units.
Tcomp Iron
Loss
Motor rated
Set the rated output of the
output
motor in units of 0.01 kW.
E2-11
This parameter is automati-
Mtr Rated
cally set during autotuning.
Power
* 1. The factory settings depend on the Inverter capacity. The values for a 200 V Class Inverter of 0.4 kW are given.
* 2. The setting range is 10% to 200% of the Inverter's rated output current. The value for a 200 V Class Inverter of 0.4 kW is given.
For the motor no-load current, set E2-03 to a value less than that of E2-01.
* 3. The setting range depends on the Inverter capacity. The value for a 200 V Class Inverter of 0.4 kW is given.
* 4. The lower limit of E2-08 is the setting value of E2-07.
Manual Motor Parameter Setting Methods
The motor parameters settings methods are given below. Make (enter) settings referring to the motor test
report.
Motor Rated Voltage Setting
Set E2-01 to the rated current on the motor nameplate.
Motor Rated Slip Setting
Set E2-02 to the motor rated slip calculated from the number of rated rotations on the motor nameplate.
Amount of motor rated slip = Motor rated frequency (Hz) - No. of rated rotations (min
poles/120.
Motor No-Load Current Setting
Set E2-03 to the motor no-load current using the rated voltage and rated frequency. The motor no-load current
is not normally written on the motor nameplate. Consult the motor manufacturer.
Factory setting is the no-load current value for a standard Yaskawa 4-pole motor.
Number of Motor Poles Setting
E2-04 is displayed only when V/f control method with PG or flux vector control method is selected. Set the
number of motor poles (number of poles) as written on the motor nameplate.
Setting
Description
Range
0.0 to
10.0
0 to
65535
0.00 to
650.00
Control Methods
Change
Factory
during
V/f
Open
Setting
Opera-
V/f
with
Loop
tion
PG
Vector
0.0
No
No
No
No
14 W
No
A
A
No
*1
0.40
No
Q
Q
kW
*1
Individual Functions
Regis-
Flux
ter
Vec-
tor
A
316H
No
317H
Q
Q
318H
−1
) x No. of motor