Replacing the software feature key

To replace the software feature key

Step
1
2
3
Copyright © 2007, Nortel Networks
.
Push the clips at each end of the DIMM sockets outward to the
open position.
Remove all the DIMMs.
Holding each DIMM by the edges, remove it from the anti-static
envelope.
Position the DIMM above the socket and align the small notch in the
bottom edge of the DIMM with the keys in the socket.
Insert the bottom edge of the DIMM into the socket.
Push down on the top edge of the DIMM until the retaining clips
snap into place. Ensure the retaining clips are fully closed so that
the DIMM can make proper contact with the server board.
Install the other DIMM.
Replace the server cover.
Plug in the peripheral devices and Ethernet cables, connect the AC
power cords, and restart the server.
Action
Remove the dongle software feature key from the server.
To eject the software feature key you must open the access door.
a. Insert a very small screwdriver into the side-access hole and
gently pull back on the access door.
b. Eject the old software feature key.
Insert the new software feature key into the software feature slot on
the dongle with the data contact facing down and away from the
embossed i.

Nortel CallPilot

600r Server Maintenance and Diagnostics

NN44200-703 01.04 Standard

5.0 25 April 2007