Power Over Ethernet (Poe) Support; Output Signals Electrical Specifications - Teledyne FLIR A68 Series User Manual

Table of Contents

Advertisement

Power over Ethernet (PoE) Support

The FLIR A68/A38 series requires a PoE Class 0 or Class 1 (or greater) power
source for the network if not using a separate external power source connected
to pins 1 & 2 of the camera's I/O Connector.
To use PoE, the camera network setup requires a powered computer NIC
supporting PoE, or a PoE capable Ethernet switch, or an Ethernet power injector.
Important: Connect power via the I/O connector or PoE, but not both.
Although FLIR A68/A38 series has protection, differences in ground levels
may cause operational issues or electrical faults.
When using PoE, the camera's I/O pin 1 (Camera Power – Ground) and
pin 2 (Camera Power- Power) must not be connected.
If both supplies are connected and active, the FLIR A68/A38 series will
use the I/O power supply connector. But as stated, ground differences
may cause camera faults or failure.

Output Signals Electrical Specifications

Opto-Coupled External Output (Pin 6)
Block Diagram
Output Common Power
Output 1 (pin 6)
External Output Details and DC Characteristics
Programmable output mode such as strobe, event notification, etc
(see
LineSource
Outputs are open on power-up with the default factory settings
A software reset will not reset the outputs to the open state if the outputs are
closed
A user setup configured to load on boot will not reset the outputs to the open
state if the outputs are closed
No output signal glitch on power-up or polarity reversal
Typical Operating Common Power Voltage Range: +3V to 28Vdc at 24mA
Maximum Common Power Voltage Range: ±30Vdc
Maximum Output Current: 24mA
FLIR A68/A38 Series IR Camera User's Manual
(pin 4)
Protection
feature)
Technical Specifications • 149

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flir a38 series

Table of Contents