The status of the Alarms can be reported as pixel values in the image. The
location of the overlay can be specified and consists of a consecutive segment of
3 pixels, each representing an alarm, with the pixel value 0 indicating Off and
the highest pixel value for the image format indicating On (255 or 65545 for 8
and 16-bit; for YUYV the 8-bit Y component is used).
Alarm ON
Alarm OFF
When triggered, an alarm remains in the On state until it is reset. Alarms are
configured using the features available in the
Related GigE Vision Features
The overlayGlobalMode, overlaySelector, overlayMode,
overlayPositionY
features control the graphic overlays and are part of the Overlay
Control Category.
58 • Features and Configuration Options
Alarm Pixel
1 2 3
Event Control
overlayPositionX
FLIR A68/A38 Series IR Camera User's Manual
category.
and