I/O Controls Category; I/O Controls Feature Descriptions; Figure 54: Camexpert I/O Controls Category; Table 25: I/O Controls Feature Descriptions - Teledyne FLIR A68 Series User Manual

Table of Contents

Advertisement

I/O Controls Category

The I/O Controls category, as shown by CamExpert, groups features used to configure
an external trigger input and acquisition actions based on the trigger. For more
information on connecting an external trigger input, see the 10-pin I/O Connector
Details section.

I/O Controls Feature Descriptions

The following table describes these features along with their view attribute.

Table 25: I/O Controls Feature Descriptions

Display Name
Line Status (All)
Line Selector
Line 1
Line 2
Line Name
Connector Pin Numbers
126 • Operational Reference

Figure 54: CamExpert I/O Controls Category

Feature & Values
LineStatusAll
LineSelector
Line1
Line2
lineName
linePinAssociation
Description
Returns the current status of all available
line signals, at the time of polling. The order,
from LSB, is Line1, Line2, ....
Selects the physical line (or pin) of the
external device connector to configure.
Index of the physical line to use. On the FLIR
A68/A38 series, Line1 is an input and
corresponds to Pin 5 of the I/O connector,
with the common ground on Pin 3.
Index of the physical line to use. On the FLIR
A68/A38 series, Line2 is an output and
corresponds to Pin 6 of the I/O connector,
with the common power on Pin 4.
Name of the selected general input/output
line.
Displays the description of the physical
pin(s) associated with the logical line. The
following abbreviations are used:
GPI = General Purpose Input
GPO = General Purpose Output
CMN_GND = Common Ground
CMN_PWR = Common Power
FLIR A68/A38 Series IR Camera User's Manual
View
Beginner
Beginner
Beginner
DFNC
Beginner
DFNC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flir a38 series

Table of Contents