Auxiliary Current And Battery Capacity; Environmental; Physical Dimensions And Weight - Interlogix xGenConnect NXG-4 Installation And Programming Manual

Hide thumbs Also See for xGenConnect NXG-4:
Table of Contents

Advertisement

Auxiliary Current and Battery Capacity

xGenConnect (EMEA)
Discharge
Charge
Time
Time
NXG-4
12 h
72 h
24 h
48 h
NXG-8(E)
12 h
72 h
24 h
48 h
NXG-9
12 h
72 h
24 h
48 h
Note:
Main board quiescent current is included in the table above.
Example for EN Grade 2
When using battery backup as specified for EN Grade 2 using a 7.2 Ah battery,
the maximum available auxiliary current is 470 mA.

Environmental

Operating temperature
Humidity
IP protection grade
NXG-4, NXG-8(E) metal enclosure
NXG-9 polycarbonate enclosure
Alarm transmission class EN50136-2/EN 50131-10:
Onboard IP
Cellular
NXG-1820 ACE classification
NXG-183x ACE classification

Physical Dimensions and Weight

Product
Main description
NXG-4(-RF)(-Z)
xGenConnect /w metal
enclosure
xGenConnect Installation and Programming Guide
7.2 Ah
12 Ah
Battery
Battery
475 mA
N/A
175 mA
N/A
475 mA
875 mA
175 mA
375 mA
450 mA
850 mA
150 mA
350 mA
18 Ah Battery
Reference
N/A
EN 50131 Grade 1 and 2
N/A
INCERT Grade 2
1200 mA
EN 50131 Grade 1 and 2
625 mA
INCERT Grade 2
N/A
EN 50131 Grade 1 and 2
N/A
INCERT Grade 2
−10 to +55°C
95% non-condensing
IP30
EN 50131 Grade 2, Class II
EN 50131 Grade 2, Class II
SP4 & DP3
SP4 & DP3
Type A
Type A
Dimensions (HxWxD)
214 x 232 x 94 mm (enclosure
only)
359 x 232 x 94 mm (with
antennas)
Weight (g)
1435 g