Wiring the Power Transformer

Connect the power transformer to the panel AC terminals as
shown in Figure 10.
Note
Do not plug in the transformer at this time.
A C
A C
Figure 10. Connecting the Power Transformer

Powering Up the Panel

When applying power to the panel connect the battery first,
then plug in the AC power transformer. This sequence prevents
a battery fault condition.

Installing the Panel Backup Battery

1.
Position and push the battery between the 2 flexible
tabs (A in Figure 11).
2.
Slide the battery to the left until the tabs snap into
place, securing the battery (B in Figure 11).
A
-
Tabs
+
+ -
Figure 11.Installing the Panel Backup Battery
Beta Test 8/10/01
H W I N 1
D C O U T
H W I N 2
B
-
+
+ -
3.
Connect the red and black battery leads (included with
panel) to the battery and panel terminals (see Figure
12).
-
Black
+
Red
Figure 12.Connecting the Battery Leads to the Battery
and Panel Terminals

Applying AC Power

Note
Make sure the outlet is not controlled by a switch or that it
is not part of a ground fault interrupt circuit (GFIC).
1.
Remove the center screw from the outlet cover plate
and hold the cover plate in place.
WARNING!
Use extreme caution when securing the trans-
former to a metal outlet cover. You could receive a
serious shock if a metal outlet cover drops down
onto the prongs of the plug while you are securing
the transformer and outlet cover to the outlet box.
2.
Plug the transformer into the lower receptacle of the
outlet so that the hole in the transformer tab lines up
with the outlet cover screw hole. The panel voice
should announce "Hello, system n is o.k."
3.
Insert the cover plate screw through the transformer tab
and the outlet cover plate. Tighten the screw firmly.

Installing X-10 Modules

Lamp and Appliance Modules

1.
Set the unit code dial to a unit number different from all
other X-10 modules (between 1 and 8).